5V 6A 512 Channel Li-ion Battery Charging Discharging Tester
Features
This 5V 6A 512-channel Li-ion battery charging and discharging tester is a highly specialized piece of equipment used in industries like electronics manufacturing, battery production, and quality control. This machine is designed to simultaneously test the capacity and internal resistance of a large number of Li-ion battery cells, making it an essential tool for ensuring quality and reliability.
Features
1. Each channel can be started and stopped at a single point, and the response speed is fast.
2. The operation is simple, convenient and intuitive.
3. Modular design, easy to maintain..
4. The digital current and voltage automatic calibration function.
5. Using network connection and SQL database.
6. The hardware technology is advanced, stable and durable.
7.Suitable for testing 18650,21700,26650,32650,32700 battery cell.
Specification
Structure Of Equipment (Device) | ||||
Number of device channels | 512 Channels | |||
Size (width * depth * height) cm | 160*55*184 | |||
Clamp form | Cylindrical four-wire fixture | |||
Color of device | Dark grey | |||
Clamp center distance | 40mm/35mm | |||
Support battery height | Adjustable within 10-100mm range | |||
Working power | Three-phase five-wire system ac380v±10%, 50hz | |||
Working power dissipation | ≤27Kw | |||
Work environment | Temperature 0-40 ℃, relative humidity ≤80% | |||
Heat-dissipating method | Natural wind intake and upward exhaust | |||
Channel Parameter | ||||
Voltage testing range | 0-5V, 1MV resolution | |||
Battery voltage range | Charge 0-4.5V: Discharge 4.5-2V | |||
Constant voltage range | 2.5V-4.5V | |||
Voltage accuracy | ±(1‰ reading +1‰ full) | |||
Current range | 60mA-6A,Resolution: 1mA | |||
Current accuracy | ±(1‰ reading +1‰ full) | |||
Control mode | Computer connection equipment work, Whole Machine Control | |||
Software Function | ||||
Communication mode | Rs485, baud rate 57,600 | |||
Process set | Maximum 32 work steps and 256 cycles | |||
Charging mode | Constant current, constant voltage | |||
Charging cutoff condition | Voltage, current, time, capacity | |||
Discharge | Constant current | |||
Discharge cut-off condition | Voltage, time, capacity | |||
Protection function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc | |||
Time range | 0 - 30,000 minutes | |||
Time accuracy | ≤±1‰ | |||
Sampling inspection period | ≤8s | |||
Minimum data recording frequency | ≤8s | |||
Battery grading | By capacity, time, discharge platform, etc | |||
Data processing | Data, graphs, and loop diagrams |
Product Details