Multi-channels Lithium Ion Cylindrical cell Battery Capacity Tester
Description
*Voltage and current: 5V/2A; 5V/3A; 5V/5A; 5V/6A; 5V/10A etc
*Channels: 96,128,256,512,768 or others.
*Battery type: Cylindrical cell 18650 21700 26650 32650 32700 etc
*Support battery height: Adjustable within 10-100mm range
*Working power: Three-phase five-wire system AC380V±10%, 50HZ
*Voltage measuring range 0-5V, 1MV resolution
*Battery voltage range: Charge: 0-4.5V; Discharge: 4.5-2V
*Constant voltage range 2.5V-4.5V
Features
Each channel can be started and stopped at a single point, and the response speed is fast.
The operation is simple, convenient and intuitive
Modular design, easy to maintain.
The digital current and voltage automatic calibration function
Using network connection and SQL database
The hardware technology is advanced, stable and durable.
Specification
Product Display
Working power
Three-phase five-wire system AC380V±10%, 50HZ
Work environment
Temperature 0-40 degrees, relative humidity ≤80%
Heat-dissipating method
Take in the wind naturally and exhaust it upward
Channel Parameter
Voltage measuring range
0-5V, 1MV resolution
Battery voltage range
Charge 0-4.5V: Discharge 4.5-2V
Constant voltage range
2.5V-4.5V
voltage accuracy
±(1‰ reading +1‰ full)
Current accuracy
±(1‰ reading +1‰ full)
Software Function
Control mode
Computer connection equipment work, FCL control
Communication mode
RS485 baud rate 57,600
Process set
A maximum of 32 work steps and 256 cycles are se
Charging mode
Constant current, constant pressure
Charging cutoff condition
Voltage, current, time, capacity
Discharge
constant current
Discharge cut-off condition
Voltage, time, capacity
Defensive function
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc
Time range
Set it anywhere from 0 to 30,000 minutes
Time accuracy
≤±1‰
Sampling inspection period
≤8S
Minimum frequency of data recording
≤8S
Battery sorting
By capacity, time, discharge platform, etc
Data processing
Data, graphs, and loop diagrams
Package