5V 60A 64 Channel Energy-feedback Lithium ion Prismatic Battery Test Equipment
Equipment features and appearance structure:
System Features:
1.The single point is independent, and the charging and discharging steps can be set independently for each battery test channel.
2.The accuracy of the equipment is 0. 05%, the data recording time is 1s / time, and the stability is high.
3.The software has powerful function and friendly man- machine interface.
4.Four wire test interface ensures high measurement accuracy.
5.Modular design concept, easy to maintain.
Equipment Structure:
1.Independent CPU board, double keyboard board, front and back double side operation, the whole cabinet unified transmission control;
2.4-channel constant current and constant voltage control module
3.Two way AC / DC invertor module;
4.Pneumatic automatic clamping mode.
Structure and Working Principle:
System composition
1.Lithium battery formatting and capacity grading equipment.
2.Computer with USB interface (self provided).
3.USB to 485 interface converter and communication line or five kinds of conmunication line and crystal head.
4.Battery scanning system.
5.ACEY product software.
System principle
The equipment is connected and controlled by computer, sending instructions and collecting data; The keyboard can manually operate the equipment and display parameters and status; Under the command of CPU, the constant current board has the function of constant current and constant voltage. When the battery is charged, the two way power supply converts the AC into 12V DC, and the charging control and detection of the battery are realized through the constant current board. When the battery is discharged, the process is opposite to charging, the battery voltage is raised to 12V by constant current plate first, and then the direct current is converted into alternating current by two-way power supply, which is fed into the AC distribution network of the factory, so as to realize the energy feedback of battery discharge energy. Energy saving effect is remarkable: the actual measurement shows that the power consumption of the equipmentfenrong is reduced by more than 40% compared with the traditional equipment, the comprehensive power saving rate is more than 60%, and the power consumption is saved by more than 60%, which saves a lot of costs for battery manufacturers.
Main technical parameters:
Number of equipment channels |
64 channels |
External dimension |
Length 920* width 1028* height 1843 (The size is subject to the actual model) |
Chassis Color |
Standard gray-white /gray-black (can be customized) |
Clamp type |
Power battery probe clamp & Alligator clamp (optional) 81mm |
Clamp spacing |
Delicated battery tray |
Support battery specifications |
Battery compatible dimensions: length 65-230mm; thickness 16- 72mm; height 80-230mm; battery tab center distance 45-150mm. |
Channel control mode |
Each battery has an independent constant current and constant voltage source, which is stable and shock-free, and can realize start, stop, pause, continuation and protection. |
Each channel has independent constant voltage and constant current hardware control circuit. |
|
The accuracy of charging current and discharging current of each channel can be calibrated automatically by software. |
|
Working power supply |
Three-phase five-wire system AC380V±10%, 50Hz |
Energy-saving feedback performance indicators |
|
Energy saving mode |
Discharge energy back to the grid |
Power factor |
0.99@220VAC, full load, grid THDu ≤2% |
Current harmonics |
<5% @220VAC, full load, grid THDu ≤2% |
Power department efficiency index |
Charge ≥80%, discharge ≥70% |
Grid connection voltage |
176-264V AC |
Grid connection frequency |
47-53 Hz |
Working power consumption |
≤ 23KW |
Bidirectional drive mode |
Synchronous rectification |
Discharging back to the grid mode |
Same frequency and same amplitude |
Feed islanding protection function |
Support |
Power section protection function |
1. Grid voltage over-limit protection 2. Grid frequency over-limit protection |
Channel measurement method |
Standard four-wire measurement |
Working environment |
Temperature -10~40, relative humidity 80% |
Status remark |
Status tri-color light |
Cooling method |
Natural air intake, upward exhaust |
Work environment |
Teaperature -10~40°C. Relative homidity 80% |
Heat dissipation mode |
Natural wind in, upward exhaust |
Channels parameters |
|
Charging constant voltage mode |
Hardware constant voltage, constant current and constant voltage conversion smooth without impact. |
Voltage measurement range |
DC 0~5V |
Battery voltage range |
Charge DC 0~4.5V; discharge DC 4.5~2V |
Constant voltage range |
DC 2~4.5V |
Voltage accuracy |
±0.05%FS, resolution 0.1mV |
Voltage stability |
≤(±1mV) |
Voltage temperature coefficient |
(±0.001%rdg.±0.3dgt.)/ ℃ |
Current range |
Charge DC 100mA~60A; Discharge DC 100mA~60A |
Current accuracy |
±0.05%FS, resolution 0.1mV |
Current stability |
≤(±1mA) |
Current temperature coefficient |
(±0.01%rdg.±0.3dgt.)/ ℃ |
Current rise time (90% Load) |
≤50ms |
Channel startup time (90% load) |
≤50ms |
Time range |
0~3000 min / step |
Time accuracy |
≤±1% |
Sampling inspection cycle |
1s-60s optional |
Product Details