  • Product Detail

48 Channels 100A Energy Feedback Prismatic Battery Charge Discharge Tester



Product Description:

Prismatic Battery Charge Discharge Tester is mainly composed of computer, communication interface and battery testing cabinet. Battery testing cabinet consists of a jig and a board body for placing the jig, constant current and constant voltage source, sampling circuit, dividing capacity control circuit, microcontroller and control panel. It is mainly used for power battery capacity separation, capacity testing and Cycle life testing, and is the mainstream in the field of power battery testing equipment to meet the needs of power battery.


Equipment Features and Appearance Structure


System Features:

●Single point independent, independent constant current and constant voltage source, stable without impact. Functions such as start, stop, pause, resume and protection can be realized.

●The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.

●The software has powerful functions and friendly man-machine interface.

●Four-wire test interface to ensure high measurement accuracy. Modular design concept, easy to maintain.


Equipment Structure:

1.Independent CPU board, double keyboard board, unified sending control of the whole cabinet;

2.8-channel constant current and constant voltage control module;

3.Bidirectional AC/DC inverter module;

4.Tray-type automatic clamping and clamping (cylinder) mode.


System structure and working principle


System Composition

1.Lithium battery is converted into capacity equipment.

2.Computer with USB interface (bring your own).

3.USB to 485 interface converter or five types of communication lines and crystal heads.

4.Battery scanning system.

5.ACEY product software.


Specification:

Equipment structure

Number of Device Channels

The whole machine has 48 channels

Exterior dimension

Width 1009mm × Length 800mm × Height 1843mm

Chassis Color

Standard gray black (customizable))

Fixture form

Power battery flat head clamp

Clamp spacing

81mm

Support battery specifications

Battery compatible Length 90-220mm; Thickness 15-70mm; Height 80-230mm; Battery

Ear 60-150mm

Channel Control Mode

Each battery has a completely independent constant current constant voltage source, stable and no impact. Realizable start

move, stop, pause, continue and protect

Each channel has an independent constant voltage, constant current hardware control circuit

Each channel charging current, discharge current accuracy can be automatically calibrated by software

Working power supply

Three-phase 5 wire system AC380V ± 10%,50HZ

power factor

≥ 0.99

AC current distortion rate

≤ 2%

Power Department Efficiency Index

Charging ≥ 80%, discharging ≥ 75%

Working power consumption

≤ 29KW

equipment failure rate

<1%

Working environment

Temperature -10~40, relative humidity 80%

Heat dissipation mode

Natural air intake, upward exhaust

smoke alarm

Optional

Power component protection function

1. Grid voltage overrun protection

2. Power grid frequency overrun protection

Channel Parameters

Voltage measurement range

DC 0~5V

Battery voltage range

Charge DC 0~4.5V; Discharge DC 4.5~1.5V

Constant voltage range

DC  2~4.5V

Voltage accuracy

±(0.5 reading  +0.5  full)

Voltage control resolution

0.1mV

Voltage sampling resolution

0.1mV

voltage stability

≤(± 1mV)

Current range

Charging DC 200mA ~ 100A; Discharging DC 200mA ~ 100A

Current accuracy

±(0.5 reading  +0.5  full)

Current control resolution

1mA

Current Sampling Resolution

0.1mA

Current stability

≤(± 1mA)

Current rise time (90% load)

≤ 50MS

Channel startup time (90% load)

≤ 50MS

Software function

Control mode

Computer-controlled equipment work, full cabinet control, with scanning system

Communication mode

485 serial port communication (baud rate 57600 )/ TCP communication

Process Settings

Up to 32 steps and 256 cycles can be set

Charging mode

Constant current, constant voltage, constant current and constant voltage

Charging end conditions

Voltage, current, time, capacity,-△V

Discharge mode

Constant current, constant power, constant resistance

Product Details:

battery Charge Discharge Tester

Battery Cell Grading Machine

battery capacity tester


leave a message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
categories

Get Daily Update We’ll never share your email address with a third-party.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.