High Precision Load Cell NA2 C3
High Accuracy Weighing Sensor NA2 C3 is environmentally sealed with potting compound to ensure durability. The aluminum alloy load cell is easy to install
Key Features:
Accuracy class C3
Calibrated to national standards
Aluminum alloy material
Special Sizes and ranges available
Usage & Applications:
price
computing scales
counting scales
weighing scales
retail scales
Dimension:
NA2 C3 Specification:
Rated Capacities
60~500(kg)
Rated Output
2.0 mV/V±5%
Zero Balance
±0.0200 mV/V
Accuracy class
OIML C3
Max No.of
loadcell interval(nmax)
3000
Min No.of
loadcell interval(Vmin)
Emax/7000
Non-linearity
0.017 %R.O.
Hysteresis
0.017 %R.O.
Repeatability
0.017 %R.O.
30mins Creep
0.017 %R.O.
30mins Return
0.017 %R.O.
Safe Overload
150 %R.O.
Ultimate Overload
200 %R.O.
Temperature Effect On Output
0.0015 %R.O./℃
Temperature Effect On Zero
0.002 %R.O./℃
Input Impedance
410±15 Ω
Output Impedance
350±5 Ω
Insulation Impedance
≥5000 MΩ/(50VDC)
Recommended Excitation
5~12 VDC
Maximum Excitation
15 VDC
OperatingTemperatureRange
-20~60 ℃
Construction
Aluminum Alloy
Protection Class
IP66 / IP67
Cable
φ5×1.5m
Recommended Platform Size
350×450 mm;400×500 mm
Mode of Connection
Red(EXC+),Black(EXC-),Green(SIG+),White(SIG-)