64 Channel 5V 60A Prismatic Battery Charge Discharge Capacity Tester
Product Description:
Battery Cell Formation and Grading System is mainly composed of computer, communication interface and battery testing cabinet. Battery testing cabinet consists of a jig and a board body for placing the jig, constant current and constant voltage source, sampling circuit, dividing capacity control circuit, microcontroller and control panel. It is mainly used for power battery capacity separation, capacity testing and Cycle life testing, and is the mainstream in the field of power battery testing equipment to meet the needs of power battery.
Equipment Features and Appearance Structure
System Features:
●Single point independent, independent constant current and constant voltage source, stable without impact. Functions such as start, stop, pause, resume and protection can be realized.
●The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.
●The software has powerful functions and friendly man-machine interface.
●Four-wire test interface to ensure high measurement accuracy. Modular design concept, easy to maintain.
Equipment Structure:
1.Independent CPU board, double keyboard board, unified sending control of the whole cabinet;
2.4-channel constant current and constant voltage control module;
3.Bidirectional AC/DC inverter module;
4.Pneumatic automatic clamping mode.
System structure
1. Lithium battery formatting, capacity grading equipment.
2. Computer with USB interface (self provided).
3. USB to 485 interface converter and communication line or five kinds of communication line and crystal head.
4. Battery scanning system.
5. ACEY product software.
Specification:
Number of equipment channels
The whole machine has 64chs
External dimension
Length 968* width 901* height 1840 (customized version, the size is subject to the actual model
Case color
Standard gray / black (customizable)
Clamp type
Custom
Clamp spring
78.5MM
Support battery specifications
The battery range is 65-220mm in length, 20-74mm in thickness, 90-230mm in height, and 45-160mm in polar ear. Cylinder 80-20 (note: this equipment is custom designed, only one type of negative pressure forming equipment is supported)
Channel control mode
Each channel can be started, stopped, suspended, continued and protected independently.
Each channel has independent constant voltage and current. Hardware control circuit
The accuracy of charging current and discharging current of each channel can be calibrated automatically by software
Working power supply
Three phase five wire AC380V土10%, 50Hz
Power factor
≥0.99
AC current distortion rate
≤2%
Charging efficiency of the whole machine
≥75%
Feed conversion efficiency
≥70%
Power consumption work
≤ 23KW
Equipment failure rate
<1%
Work environment
Temperature -10~40°C. Relative humidity 80%
Heat dissipation mode
Natural wind in, upward exhaust
Voltage measurement range
DC 0~5V
Battery voltage range
Charge DC 0~4.5V; discharge DC 4.5~2V
Constant voltage range
DC 2~4.5V
Voltage accuracy
±(0.05% reading + 0.05% full), resolution ratio 1mV
Voltage stability
≤(±1mV)
Current range
Charge DC 60mA~60A; Discharge DC 60mA~60A
Current accuracy
±(0.05% reading + 0.05% full), resolution ratio 1mV
Current stability
≤(±1mA)
Negative pressure range
(-100KPa-0)adjustable
Control mode
Computer control, can control the whole cabinet with scanning function
Communication mode
485s port communication (port rate 57600)/ TCP
Process settings
Up to 32 steps and 256 cycles can be set
Charging mode
Constant current; constant pressure; constant current & pressure
Charging cut-off conditions
Voltage, current, time, capacity, - △ v
Discharge mode
Permanent flow, constant power, constant resistance
Discharging cut-off conditions
Voltage, time, and capacity
Protection function
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power off protection, data breakpoint recovery
Time frame
0~3000 min / step in min
Time accuracy
≤±0.1%
Sampling inspection cycle
1s-60s optional
Battery sorting
Divide according to capacity, time, open-circuit voltage, discharge platform, etc.
Data processing
Can record voltage, current, time, capacity etc, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, provide data curve and cycle diagram; can output text, excel, word or mdb format data file
Basic function of software
1. The software supports various connections, such as manual pause continuation, software shutdown continuation, power outage, disconnection in equipment communication, abnormal stop continuation;
2. Support bar code scanning, scanning one-dimensional code, QR code, channel jump scanning, loading scanning and other scanning methods;
3. Local test detailed data storage, can view the current test data and historical data of each channel at any time, have data and curve corresponding two ways, and support excel report in single or batch form, and can set the test end automatic data export according to the need.
4. Support capacity sorting, and grade the battery sorting;
5. Support the qualified judgment after the test, and judge the pass / ng results according to the specified cycle capacity, voltage, time and other information;
6. Support various step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, overdischarge protection test;
7. Support channel parallel (according to equipment);
8. Support unit conversion;
9. Support database server background storage or MES docking;
10. Software offline protection;
Product Details: