4 Channel 100V 20A Charge 40A Discharge Battery Aging Machine
Description
ACEY-BT10040-4 is mainly used for testing the charging and discharging cycle of finished lithium batteries.The equipment has four test steps: charging, discharging, shelving and cycling. By editing the corresponding step, the battery can be tested according to the set process.
Equipment Function
- Charging and discharging function: with constant current and voltage charging function, constant current discharging function, charging and discharging of the battery, recording the battery capacity.
- Charging and discharging interface: fully meet the requirements of battery pack charging and discharging with the same port and charging and discharging sub-port, i.e. 2 wires (P+ P-), 3 wires (P+ P- C-) and positive plate charging protection, negative pole charging protection. 3 wires (P+ P- C-) and positive plate charge protection, negative plate discharge protection of power tool batteries (CH+ P+ P-).
- Checking voltage protection:detecting whether the battery charge protection and discharge protection are working by charging and discharging the battery.
- Safety protection:anti-reverse connection protection function, power-down data protection, support continuous measurement, voltage upper and lower limit setting protection, and
- safe discharge current protection.
- Online mode: the instrument can be connected to PC through serial port for single unit or less than 5 units; for more than 5 units, a network connection mode is adopted and a network port is provided at the PC side to control up to 30 units.
- Control system: The software system adopts the classical and mature C/S mode, with two modes of communication: serial port can achieve accurate communication of several instruments in short distance, and network can achieve accurate communication of multiple instruments in long distance.
Specification
Model No. | ACEY-BT10040-4 | |
Voltage | Test range | 10~ 100V |
Accuracy | ± (0.2% of reading + 0.2% of range) | |
Current | Charge | 200~20000mA |
Discharge | 200~40000mA | |
Accuracy | ± (0.2% of reading + 0.2% of range) | |
Charge | CV cut-off current | Min 50mA |
Capacity | Accuracy | ±1‰ |
Power | Discharge power | ≤4000W |
Time | Patrol time | actual time<2S |
Timing range | 0~999 h/work step | |
Data logging interval | ≥5S | |
Communication box version | 1. 1 series | |
Charge | Charge mode | CCCV charge |
Cut-off condition | Voltage,current,relative time,overcharge protection | |
Discharge | Disharge mode | CC discharge |
Cut-off condition | Voltage, relative time,overdischarge protection | |
cycler | Cycle measurement range | 1~999 times |
Number of work steps in a single cycle | 100 |
Product Display