18650 26650 Battery Pack Aging Cabinet Lithium Battery Charging& Discharging Testing Machine
Description
ACEY-BT10020-7 is mainly used for lithium battery charging and discharging cycle test. The test items include battery charging protection voltage, discharging protection voltage, capacity, etc. The equipment has four test steps: charging, discharging, shelving and cycling. By editing the corresponding step, the battery can be tested according to the set process.
Features
1. In the network mode, it is connected automatically, without manual
2. Use MYSQL database to save data to ensure that data will not be lost, and provide measurement data review function.
3. A small number of instruments can communicate with PC software through the serial port.
4. Multiple instruments can use the network to communicate with PC software, which reduces the computer interface. Only one network port is needed to control all instruments, ensuring the real-time and complete communication data.
5. The instrument number is displayed through LED lights, and the position of the corresponding instrument can be queried intuitively. The number can be modified by software, which reflects the flexibility of the instrument.
6. In addition to the P+ and P- interfaces, the instrument also provides CH+ and CH-, which can test special finished batteries and charge and discharge them on one instrument.
7.The battery can be charged as long as the battery is in the test range, avoiding the problem that the charger can only charge a specific type of battery.
Specification
Model No. |
ACEY-BT10020-7 |
Charging function |
With constant current and constant voltage charging function |
discharge function |
With constant current and current limiting discharge function |
Charge and discharge interface |
Fully meet the requirements of charging and discharging the same port and separate charging and discharging of the battery pack, that is, 2 wires (P+ P-) and 3 wires (P+ P- C-) |
Equipped with a usb interface |
It is used for scanning gun to collect the ID number of the battery pack, which is convenient for data query after battery aging |
Security protection |
Anti-reverse protection function |
Voltage upper and lower limit setting protection |
|
Safe discharge current protection (maximum current 10A) |
|
Charging requirements |
Charging voltage 0-100V, continuously adjustable, accuracy ±1mV(high precision dedicated) |
Charging current 0-10000mA, continuously adjustable, accuracy ±1mA (high precision dedicated) |
|
Discharge requirements |
Discharge voltage 0-100V, accuracy ±1mV (high precision dedicated) |
Discharge current 0-10000A, accuracy ±1mA (high precision dedicated) |
|
Discharge current 0-20A, accuracy ±1mA (high precision dedicated) |