100V 30A Charge 120A Discharge Lithium Battery Integrated Tester
Description
Lithium battery integrated tester is a fast and accurate device to test the performance of finished battery. It can measure the open circuit voltage, internal resistance, charge, discharge, overcurrent protection, short circuit protection and other functions of the battery. It can easily detect bad batteries and increased production efficiency.
Testing items
*Voltage: No-load voltage and Short circuit protection voltage after the test is completed, Range:0-100V.
*Internal Resistance: ACIR1000hz, Range:0-4000mΩ
*Charging overcurrent protection current , Range:0-30A.
*Continuous charging current, Range:0-30A.
*Continuous charging voltage monitoring, Range:0-100V.
*Discharge overcurrent protection current and delay time, current range:0-120A.
*Overcurrent test mode: (1) Step test (2) quick test.
*Continuous discharge current, Range:0-120A
*Continuous discharge voltage judgment, Range: 0-100V
*Short circuit protection time:≤1000μS, Max short circuit current about 5000A
*Single cell voltage monitoring
*Appreciation of charge and discharge voltage: During the working test, if the power supply is cut off and the MOS tube of the protection board is turned off, no inrush current will be generated, and the protection board of the lithium battery pack will not be damaged.
*Support MES system
*Database: The software comes with a database, which can generate excel tables.
*Step-by-step mode: the test sequence can be adjusted automatically.
*Support chassis expansion.
Technical Parameters
*Voltage range: 0-100V Resolution:1mV Accuracy: 0.1%RD+0.1FS
*Internal resistance: 0-2000mΩ Resolution:0.001mΩ Accuracy: 0.1%RD+0.1FS
*Charge current: 0-30A Resolution: 0.001A Accuracy: 0.1%RD+0.1FS
*Discharge current 0-120A at the highest voltage, continued discharge current 120A,
Resolution: 0.001A Accuracy: 0.1%RD+0.1FS
*Overcurrent delay time: 0-30S Resolution: 1mS Accuracy: 0.1%RD+0.1FS
*Short circuit time: 0-2000μS Resolution: 1μS Accuracy: 0.1%RD+0.1FS
*NTC range: 0-100K 0.001K
*R1 range: 0-100K 0.001K
*Power supply: AC 200V-240V
*Maximum working power for charging:3000W (When charging with maximum current)
*Surge voltage:<15V
Equipment requirements:
*Equipment operating environment: ventilated and dry plant.
*Working environment: temperature -10℃~40℃/humidity: 10%~90%
*Equipment operation mode: upper computer control, manual test.
*The equipment comes with NG alarm device (buzzer)
Product Details