1-45 Series 300A Battery Management System Tester
Product Description
1-45 series 300A bms tester with high degree of automation, fast testing speed and high testing accuracy. With test overcharge, overcharge recovery, overdischarge, overdischarge recovery, overcurrent (overcharge current and overdischarge current), internal resistance, self-consumption, short-circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection time, equalization current, equalization voltage, 13 performance.
Can meet the current market lithium ternary batteries, lithium iron phosphate batteries and cobalt acid battery protection plate test, with lithium ternary batteries, lithium iron batteries and cobalt acid battery test gear switching function.
The instrument requires connection to a computer, computer hardware configuration requirements for general office computers can be, the system generally requires XP system, the instrument and the computer using industry-standard 232 interface.
Parameter
1. Cycle: cycle times:1~9999 times
2. Using the programming, the number of times the device carries out an uninterrupted cycle of the various indicators of the protection board.
3. Log tracking
4. With log function, including testing the entire process of operation records, exception records, can be used to test the process of tracing.
5. Data processing, man-machine interface
6. Test data is saved in EXCEL file.
7. The RS232 interface is used for the interface between the device and the upper computer, which can ensure the stability and real-time data acquisition.
8. Accuracy calibration / software calibration
9. with a sweep start function
10.MES system connection
13. Active balancing (customizable)
14. Balanced current (can be customized)
15. Communication protocol test (optional)
Test Functions
No. | Function | Setting range | Testing accuracy | Unit |
1 | Single section self-consumption | 0--500 | ±0.1 | uA |
2 | Self-consumption | 0--5000 | ±1 | uA |
3 | Overcharge protection voltage | 500--5000 | ±1 | mV |
4 | Overcharge protection release voltage | 500--5000 | ±1 | mV |
5 | Overcharge protection delay time | 0--10000 | ±1 | mS |
6 | Over-discharge protection voltage | 500--5000 | ±1 | mV |
7 | Over-discharge protection release voltage | 500--5000 | ±1 | mV |
8 | Overcharge voltage protection delay time | 0--10000 | ±1 | mS |
9 | Overcharge current protection value | 0.1--500 | ±0.01 | A |
10 | Overcharge current protection delay time | 0--20000 | ±1 | mS |
11 | Overcharge current protection value | 0.1--800 | ±0.01 | A |
12 | Over discharge current protection delay time | 0.1--20000 | ±1 | mS |
13 | Equalizing opening voltage | 500--5000 | ±1 | mV |
14 | Equalizing Current | 1--500 | ±1 | mA |
15 | Charging Aging Current | 0.1--200 | ±0.01 | A |
16 | Discharge Aging Current | 0.1--200 | ±0.01 | A |
17 | Charging aging time | 0--30 | ±1 | S |
18 | Discharge current aging time | 0--60 | ±1 | S |
19 | Single section self-consumption difference | 0-500 | ±0.1 | uA |
20 | Resistance | 0-999 | ±1 | mΏ |
21 | Short circuit protection time | 0--5000 | ±1 | uS |
22 | Charging aging voltage | 500--5000 | ±1 | mV |
23 | Single discharge aging voltage | 500--5000 | ±1 | mV |
24 | Open circuit voltage | 102000 | ±1 | mV |
25 | Number of voltage simulations | 32 | 0 | PCS |